DUAL DIGITAL FIBER
SENSOR
FS-V21/21G/21R(P)/21X
Instruction Manual
3. Mounting Unit
G DIN Track Mounting
1) As shown in the illustration, engage
the claw on the lower side of the
unit and the DIN rail, press the unit
in the direction shown by arrow ,
and move down the unit in the di-
rection shown by arrow .
2) When dismounting the unit, press
the unit in the direction shown by
arrow and move up the unit in
the direction shown by arrow .
G Using Mounting Bracket (accessory)
• Attach the unit to the mounting
bracket, mount them together, and
secure them with two M3 screws
as shown in the illustration.
1. Safety Precautions
WARNING
• This product is used to detect targets. Do not apply the product to
safety circuits for human protection.
• This product is not of explosion-proof construction. Do not use the
products in places with flammable gas, liquid, or dust.
• This product is a sensor of DC power supply type. Do not apply AC
power. The product may explode or burn if 100 VAC or a higher volt-
age is applied.
Check that all the accessories are ready before use.
• Accessories
Instruction manual (x 1)
Mounting bracket (x 1)
2. Part Names
Fiber lock lever
Operation indicator*
Digital monitor
Preset value (PV)
green indicator
Current value (CV)
red indicator
Dust cover
Set button
Manual button
Mode button
Expansion
protective cover
Expansion
connector
Output selector
Cable
* The operation indicator of the FS-V21X (infrared model) will not be lit.
4. Connecting Fiber Unit
Fiber insertion sign
1) Open the dust cover in the di-
rection shown by arrow .
2) Move down the fiber lock lever
in the direction shown by arrow
.
3) Insert a fiber unit into the fiber
insertion holes to a length of the
fiber insertion sign (i.e., approxi-
mately 14 mm).
4) Move up and return the fiber
lock lever in the direction shown
by the arrow .
Note:If a thin fiber unit is used, an adapter provided with the thin fiber unit
will be required.
Unless the right adapter is connected, the thin fiber unit will not
detect targets correctly.
Cable outer dia. Adapter
ø1.3
Adapter A
Appearance
ø1.0
Adapter B
• To connect the coaxial reflective type fiber unit to the amplifier, connect
the single-core fiber to the transmitter side, and connect the multiple-
core fiber to the receiver side.
Single-core fiber
Multi-core fiber
Transmitter
Receiver
5. I/O Cricuit
Refer to the following I/O circuit diagram when connecting the unit to pe-
ripheral devices.
G FS-V21/21G/21R/21X
G FS-V21RP
Brown Max. 100mA
Black
Load
Control output
12 to 24 VDC
5 to 40 VDC
Blue
0 VDC
Brown
12 to 24 VDC
Black Max. 100mA
Load
Control output
Blue
0 VDC
1

1 Page





FS-V21X pdf, ピン配列
q Display Selection (Access Mode: EASY)
PV CV
Press
Press
Excess CV
gain
Press
Output Power
status mode status
The CV is displayed in
percent based on the
PV.
The current value will be
displayed if no keys are operated
for approximately 30 s.
If the timer function is set, the
output status with power mode
and the timer mode with set time
will be displayed alternately.
q Display Selection (Access Mode: FULL)
PV CV
Press
Press
q Menu Selection (Access Mode: FULL)
Access
mode
selection
Power
mode
selection
Timer
function
setting
Press the
mode button 3 s min
Press
Select
Press
Normal operation use
FINE
Used if the sensing distance is insufficient
TURBO while the sensor is in fine mode.
Used if the sensing environment is
SUPERTURBO bad due to dust or other obstacles.
Used if the incident is insufficient while
ULTRATURBO the sensor is in SUPER TURBO mode.
Used to detect sensing objects
HIGHSPEED moving at high speed.
Used to detect delicate differences
HIGH RESO- within a short sensing distance.
LUTION
Select
Press
Other than
Timer OFF (for normal operation use)
OFF-delay timer
ON-delay timer
One-shot timer
Excess
gain CV
Output
status
Power
mode status
Press
Press
Peak
excess
gain
Bottom
excess
gain
Press
LED bar CV
indicator
Press
Peak value
Bottom value
q Menu Selection (Access Mode: EASY)
Press the
mode button 3 s min
Access mode
selection
Press
Power mode
selection
Press manual
button to select
Press
Timer function
setting
Press manual
button to select
Press
Normal
F I N E operation use
Used if the sensing
TURBO distance is insufficient
while the sensor is in
fine mode.
Used if the sensing
SUPER environment is bad
TURBO due to dust or other
obstacles.
Timer OFF (for
normal operation use)
OFF-delay timer
ON-delay timer
One-shot timer
Other than
Press
Press to manual button to
make timer adjustments
* For timer values, refer to the
corresponding table under FULL
mode.
Power mode
,
S-APC
mode
setting
Press
Other than
Power mode
,
Select
Press
Edge
detection
mode
selection
Select
Power save
function
setting
Press
Select
Power mode
Shift
function
setting
Press
Other than
Power mode
Select
Press
Timer adjustments
Timer adjustment range
1~30ms 1-ms increments
30~50ms 2-ms increments
50~200ms 10-ms increments
200~500ms 50-ms increments
* A maximum error of ±10% of the PV.
OFF (for normal operation use)
Used to detect sensing objects highly
precisely under clean environments.
OFF (for normal operation use)
Rising edge
Falling edge
OFF (for normal operation use)
ECO half
ECO all
OFF (for normal operation use)
Shift ON
Press
Shift value adjustment
Shift value CV
Sensitivity Settings in Edge Detection Mode
The sensitivity of the sensor will be set to maximum by pressing the
while the sensor is in edge detection mode. Make fine sensitivity adjust-
ments by pressing the .
Note:
Press the mode button ( ) for a minimum of three seconds to return to the display of the CV from any menu selection stage. To return to the
previous display, press the mode button ( ) first, and press the left side (
) of the manual button ( ).
When the power mode is set to HIGH RESOLUTION, the S-APC mode will be always turned ON.
When the power mode is set to HIGH SPEED, the S-APC mode will be always turned ON in the case of the R model, or otherwise the S-APC mode
will be always turned OFF.
3


3Pages





ページ 合計 : 4 ページ
 
PDF
ダウンロード
[ FS-V21X データシート.PDF ]


データシートを活用すると、その部品の主な機能と仕様を詳しく理解できます。 ピン構成、電気的特性、動作パラメータ、性能を確認してください。


共有リンク

Link :


部品番号部品説明メーカ
FS-V21

DUAL DIGITAL FIBER SENSOR

Keyence
Keyence
FS-V21G

DUAL DIGITAL FIBER SENSOR

Keyence
Keyence
FS-V21R

DUAL DIGITAL FIBER SENSOR

Keyence
Keyence
FS-V21RP

DUAL DIGITAL FIBER SENSOR

Keyence
Keyence


www.DataSheet.jp    |   2020   |  メール    |   最新    |   Sitemap