No Preview Available ! GP1U28Y Hoja de datos, Descripción, Manual

GP1U26X/27X/28X/28Y Series
GP1U26X/GP1U27X Series
GP1U28X/GP1U28Y Series
Compact IR Detecting Unit
for Remote Control
s Features
1. Compact (case volume)
(GP1U28Y : About 1/4 compared with GP1U58Y)
2. Height from PWB to detector face same as GP1U58Y
3. Power filter capacitor and resistance are not required any more
as a result of adoption of built-in constant voltage circuit
4. Various B.P.F. (Band Pass Frequency) frequency to meet different user needs
s Applications
1. AV equipment such as TV sets,
VCRs and audio equipment
2. HA equipment such as air conditioners
s Outline Dimensions
GP1U26X Series
7.3
0.5
1.6
5.2 3.6
GP1U27X Series
7.3
0.5
(Unit : mm)
1.6
10.4
3.6
Marking
Marking
*1
2.54
*1
2.54
R1.9
4
Recommended drilling as viewed from the soldering face.
3.75 3.75
1.2
2-0.5
2-0.4
2-0.75
0.6 1 2 3 0.6
1.2
Detector
center
(0.5)
1 Vout
2 VCC
3 GND
Φ 0.8
2.54
2.54
1. Unspecified tolerance : ± 0.3
GP1U28X Series
7.3
0.5
1.6
2. * 1 : The dimension of lead base
14.4
3.6
*1
2.54
*1
2.54
R1.9
4
Recommended drilling as viewed from the soldering face.
3.75 3.75
1.2
2-0.5
2-0.4
2-0.75
1 Vout
2 VCC
3 GND
0.6 1 2 3 0.6
1.2
Detector
center
(0.5)
Φ 0.8
2.54
2.54
1. Unspecified tolerance : ± 0.3
GP1U28Y Series
7.3
0.5
2. * 1 : The dimension of lead base
1.6 4
Marking
Marking
*1
2.54
*1
2.54
R1.9
4
Recommended drilling as viewed from the soldering face.
3.75 3.75
1.2
1 Vout
2 VCC
3 GND
2-0.5
2-0.4
2-0.75
0.6 1 2 3 0.6
1. Unspecified tolerance : ± 0.3
1.2
Detector
center
(0.5)
Φ 0.8
2.54
2.54
2. * 1 : The dimension of lead base
0.4
0.6 1 2 3 0.6
1.6
3.7
1.4
1.4
5.4
1 Vout
6.8
2 VCC
3 GND
R1.9
Recommended drilling as viewed from the soldering face.
2.54 2.54
0.5
*1
2.54
*1
2.54
1. Unspecified tolerance : ± 0.3
1.2 1.2
3.75 3.75
2. * 1 : The dimension of lead base
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.

1 page




GP1U28Y pdf
Fig. 5 AEHA (Japan Association of Electrical Home Appliances)
Code Pulse Width Characteristics (1st Bit) [TYP.] for Reference
700
Low level pulse width
600
500
400
300
High level pulse width
200
Unit AEHA code
100
generating transmitter
1st bit
VCC =5V, Ta=RT, φ =0˚ ,
Ee < 10 lx, T=430µ s
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Reception distance (m)
GP1U26X/27X/28X/28Y Series
Fig. 6 Spectral Sensitivity for Reference
100
90
80
70
60
50
40
30
20
10
700 800 900 1000 1100 1200
Wavelength λ (nm)
s Precautions for Operation
1) In case of adopting the infrared light detecting unit for the wireless remote control, use it in accordance
with the transmission scheme and the signal format recommended in "Countermeasures for malfunction prevention of
home appliances with remote control" issued from Japan Association of Electrical Home Appliances (AEHA) in July, 1987.
Use of a transmission scheme and a signal format different from those recommended may cause malfunction of home appliances.
(Example : signal format without leader signal, bit structure of small duty ratio (TH/(TH+T L)))
2) Use the light emitting unit (remote control transmitter), in consideration of performance, characteristics,
operating conditions of light light emitting device and the characteristics of the light detecting unit.
3) Pay attention to a malfunction of the light detecting unit when the surface is stained with dust and refuse.
Care must be taken not to touch the light detector surface.
If it should be dirty, wipe off such dust and refuse with soft cloth so as to prevent scratch. In case some solvents are required,
use methyl alcohol, ethyl alcohol or isopropyl alcohol only.
Also, protect the light detecting unit against flux and others, since their deposition on the unit inside causes reduction of the function,
fading of markings such as the part number.
4) The shield case should be grounded on PWB pattern.
(The area across the shield case and the GND terminal is internally conductive in some cases and non-conductive in some other cases.)
5) Do not apply unnecessary force to the terminal and the case.
6) Do not push the light detector surface (photodiode) from outside.
7) To avoid the electrostatic breakdown of IC, handle the unit under the condition of grounding with human body, soldering iron, etc.
8) Do not use hole and groove set in the case of the light detecting unit for other purposes,
since they are required to maintain the specified performance.

5 Page










PáginasTotal 5 Páginas
PDF Descargar[ Datasheet GP1U28Y.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
GP1U28QAnti Electromagnetic Induction Noise Type Compact IR Detecting Unit for Remote ControlSharp Electrionic Components
Sharp Electrionic Components
GP1U28RAnti Electromagnetic Induction Noise Type Compact IR Detecting Unit for Remote ControlSharp Electrionic Components
Sharp Electrionic Components
GP1U28XCompact IR Detecting Unit for Remote ControlSharp Electrionic Components
Sharp Electrionic Components
GP1U28YCompact IR Detecting Unit for Remote ControlSharp Electrionic Components
Sharp Electrionic Components

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar