DataSheet.jp

SP100-2 の電気的特性と機能

SP100-2のメーカーはSensonorです、この部品の機能は「Pressure Sensor Series」です。


製品の詳細 ( Datasheet PDF )

部品番号 SP100-2
部品説明 Pressure Sensor Series
メーカ Sensonor
ロゴ Sensonor ロゴ 




このページの下部にプレビューとSP100-2ダウンロード(pdfファイル)リンクがあります。

Total 15 pages

No Preview Available !

SP100-2 Datasheet, SP100-2 PDF,ピン配置, 機能
DATASHEET SP100 PRESSURE SENSOR SERIES
SP100-1(T), SP100-2(T)
SP100 Series
Compensated Pressure Sensors
The SP100 pressure sensors are calibrated and digitally compensated silicon piezoresistive sensors with SPI
interface. In addition to pressure these sensors provides temperature and supply voltage measurements. Each
sensor has a unique electronic sensor ID, and has a built in self diagnosis system. SP100 sensors can easily be
used in a broad range of applications and interfaces directly to a micro controller without the need of any additional
components.
SP100 series of sensors has excellent media compatibility due to a patented bulk micromachined triple stack sensor
die design, utilizing buried piezoresistive elements and backside media access to pressure diaphragm. With this
design the internal connectors and piezoresistive elements of the pressure bridge are isolated from the
measurement media. This isolation is of great importance in terms of stability and reliability of the sensor over a very
long lifetime.
The SP100 pressure sensor design has been proven in harsh environment applications during a period of more than
10 years, making these sensors ideal choices for demanding applications where simple solutions are needed to
quickly implement reliable and accurate pressure measurements.
SP100-1 and SP100-2 belongs to the lower pressure range of SP100 sensors.
SP100-1
SP100-1T
SP100-2
SP100-2T
TS1483 rev. 1
-1-

1 Page





SP100-2 pdf, ピン配列
DATASHEET SP100 PRESSURE SENSOR SERIES
SP100-1(T), SP100-2(T)
Table of Contents
1 Product Description ............................................................................................................................................... - 4 -
1.1 Features ....................................................................................................................................................- 4 -
1.2 Overview....................................................................................................................................................- 4 -
2 Measurement Performance ................................................................................................................................... - 5 -
2.1 Pressure Measurement Performance .......................................................................................................- 5 -
2.2 Temperature Measurement Performance .................................................................................................- 5 -
2.3 Supply Voltage Measurement Performance .............................................................................................- 6 -
3 Recommended Operating Conditions ................................................................................................................... - 6 -
4 Absolute Maximum Ratings................................................................................................................................... - 7 -
5 Wake-Up and Reset Outputs................................................................................................................................. - 7 -
6 Serial Interface....................................................................................................................................................... - 7 -
6.1 SPI Protocol...............................................................................................................................................- 8 -
6.2 SPI Commands .........................................................................................................................................- 9 -
6.3 SPI Timing Parameters .............................................................................................................................- 9 -
6.4 Status Byte ..............................................................................................................................................- 10 -
6.5 Temperature Byte....................................................................................................................................- 10 -
6.6 Pressure Byte ..........................................................................................................................................- 10 -
6.7 Supply Voltage Byte ................................................................................................................................- 10 -
7 Digital Output Characteristics .............................................................................................................................. - 10 -
8 Power-On Reset .................................................................................................................................................. - 10 -
9 Current Consumption........................................................................................................................................... - 11 -
9.1 Standby Current ......................................................................................................................................- 11 -
9.2 Measurement Current .............................................................................................................................- 11 -
10 Error Handling and Recovery .............................................................................................................................. - 11 -
10.1 PROM Data .............................................................................................................................................- 11 -
10.2 PROM Reload .........................................................................................................................................- 11 -
10.3 Shadow Register Protection....................................................................................................................- 11 -
10.4 Low Supply Voltage.................................................................................................................................- 12 -
10.5 High Temperature....................................................................................................................................- 12 -
10.6 Overflow/Underflow .................................................................................................................................- 12 -
11 Mechanical Specifications ................................................................................................................................... - 13 -
11.1 Physical Dimensions ...............................................................................................................................- 13 -
11.2 Tube Connection (option)........................................................................................................................- 14 -
11.3 Pin Configuration .....................................................................................................................................- 15 -
11.4 Marking....................................................................................................................................................- 15 -
TS1483 rev. 1
-3-


3Pages


SP100-2 電子部品, 半導体
DATASHEET SP100 PRESSURE SENSOR SERIES
SP100-1(T), SP100-2(T)
3
2
1
0
1
2
50
0 50 100
Temperature reported from the product [°C]
Figure 2.1 Temperature correction term
150
2.3 Supply Voltage Measurement Performance
Parameter
Input range 1)
Resolution
Accuracy
Specification
Unit
Typ
V 1.8 – 3.6
mV/lsb
18.4
mV ± 60
Ambient conditions
Supply voltage [V]
2.1 to 3.6
2.1 to 3.6
2.1 to 3.6
Delay between
ms 3.5
measurement command
and sampling
Delay between sampling ms
10
and A/D conversion
Supply voltage
ms 17 (max)
measurement total time
-
-
2.1 to 3.6
Note:
1) The sampling operates down to 1.8 V. The specification applies to the A/D-conversion.
3 Recommended Operating Conditions
Description
Temperature range, operational
Supply voltage during measurement 1)
Supply voltage between measurements
Input pressure 2)
SP100-1
SP100-1T
SP100-2
SP100-2T
Min
-40
2.1
1.8
0
0
Typ Max
+125
3.6
5.5
100
200
Notes:
1) This is the voltage range where measurement accuracy is specified.
2) All pressure values given in this specification are absolute values.
Units
°C
V
V
kPa
kPa
TS1483 rev. 1
-6-

6 Page



ページ 合計 : 15 ページ
 
PDF
ダウンロード
[ SP100-2 データシート.PDF ]


データシートを活用すると、その部品の主な機能と仕様を詳しく理解できます。 ピン構成、電気的特性、動作パラメータ、性能を確認してください。


共有リンク

Link :


部品番号部品説明メーカ
SP100-1

Pressure Sensor Series

Sensonor
Sensonor
SP100-15

Pressure Sensor Series

Sensonor
Sensonor
SP100-1T

Pressure Sensor Series

Sensonor
Sensonor
SP100-2

Pressure Sensor Series

Sensonor
Sensonor


www.DataSheet.jp    |   2020   |  メール    |   最新    |   Sitemap