DataSheet39.com

What is VXFA22?

This electronic component, produced by the manufacturer "SMC", performs the same function as "Direct Operated 3 Port Solenoid Valve".


VXFA22 Datasheet PDF - SMC

Part Number VXFA22
Description Direct Operated 3 Port Solenoid Valve
Manufacturers SMC 
Logo SMC Logo 


There is a preview and VXFA22 download ( pdf file ) link at the bottom of this page.





Total 30 Pages



Preview 1 page

No Preview Available ! VXFA22 datasheet, circuit

CAT.EUS70-26 A -UK
Direct Operated
3 Port Solenoid Valve
For Water, Oil, Steam, Air
Reduction of
power consumption
(DC specification)
6 W 4.5 W
78 W W
11.5 W 10.5 W
3New
VX Series VX31/32/33

line_dark_gray
VXFA22 equivalent
Solenoid Valves Flow Characteristics
C : Sonic conductance [dm3/(s·bar)]
b : Critical pressure ratio [—]
P1 : Upstream pressure [MPa]
P2 : Downstream pressure [MPa]
t : Temperature [°C]
Note) Formula of subsonic flow is the elliptic analogous curve.
Flow characteristics curve is indicated in the Graph (1) For details, please use SMC’s “Energy Saving Program”.
Example)
Obtain the air flow rate when P1 = 0.4 [MPa], P 2 = 0.3 [MPa], t = 20 [°C] for a solenoid valve where C = 2 [dm3/(s·bar)] and b = 0.3.
According to formula (1), the maximum flow rate = 600 x 2 x (0.4 + 0.1) x
293
————— = 600 [dm3/min (ANR)]
273 + 20
Pressure ratio = —0.3+ 0.1— = 0.8
0.4 + 0.1
Based on the Graph (1), the flow rate ratio is going to be 0.7 if it is read with a pressure ratio of 0.8 and a flow ratio of b = 0.3.
Hence, flow rate = Max. flow rate x flow rate ratio = 600 x 0.7 = 420 [dm3/min (ANR)]
1
0.9 b = 0.1
0.8 0.2
0.7 0.3
0.6 0.4
0.5
0.5
0.6
0.4
0.3 P1 Equipment P2
0.2 C, b Q
0.1
00 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Pressure ratio (P2 + 0.1) / (P1 + 0.1)
Graph (1) Flow characteristics line
(4) Test method
Pipe the text equipment to the text circuit shown in Fig. (1). Keep the upstream pressure at a certain constant level above
0.3MPa. First measure the maximum flow rate in saturation. Then, measure the flow rate, upstream pressure and downstream
pressure each at 80%, 60%, 40% and 20% points of the flow rate. Calculate the sonic conductance C from the maximum flow
rate. Also substitute other data for variables in the formula for subsonic flow and obtain the critical pressure rate b by averaging
the critical pressure rates at those points.
Pressure control
equipment
ød3 3d1
Pressure gauge or
pressure convertor
Thermometer
Differential pressure gauge or
differential pressure converter
3d3 Flow control valve
Air supply Filter
Shut off
valve
10d3
Flow meter
10d1 3d1 10d2
3d2
Pipe for measuring
temperature
Equipment
for test
Pipe for measuring Pipe for measuring
pressure in the
pressure in the
upstream side
downstream side
Fig. (1) Test circuit based on ISO 6358, JIS B 8390
Front matter 2


line_dark_gray

Preview 5 Page


Part Details

On this page, you can learn information such as the schematic, equivalent, pinout, replacement, circuit, and manual for VXFA22 electronic component.


Information Total 30 Pages
Link URL [ Copy URL to Clipboard ]
Download [ VXFA22.PDF Datasheet ]

Share Link :

Electronic Components Distributor


An electronic components distributor is a company that sources, stocks, and sells electronic components to manufacturers, engineers, and hobbyists.


SparkFun Electronics Allied Electronics DigiKey Electronics Arrow Electronics
Mouser Electronics Adafruit Newark Chip One Stop


Featured Datasheets

Part NumberDescriptionMFRS
VXFA21The function is Direct Operated 3 Port Solenoid Valve. SMCSMC
VXFA22The function is Direct Operated 3 Port Solenoid Valve. SMCSMC

Semiconductors commonly used in industry:

1N4148   |   BAW56   |   1N5400   |   NE555   |  

LM324   |   BC327   |   IRF840  |   2N3904   |  



Quick jump to:

VXFA     1N4     2N2     2SA     2SC     74H     BC     HCF     IRF     KA    

LA     LM     MC     NE     ST     STK     TDA     TL     UA    



Privacy Policy   |    Contact Us     |    New    |    Search