DataSheet.jp

VF3530 の電気的特性と機能

VF3530のメーカーはSMCです、この部品の機能は「5 Port Pilot Operated Solenoid Valve Rubber Seal」です。


製品の詳細 ( Datasheet PDF )

部品番号 VF3530
部品説明 5 Port Pilot Operated Solenoid Valve Rubber Seal
メーカ SMC
ロゴ SMC ロゴ 




このページの下部にプレビューとVF3530ダウンロード(pdfファイル)リンクがあります。

Total 30 pages

No Preview Available !

VF3530 Datasheet, VF3530 PDF,ピン配置, 機能
1
5 Port Pilot Operated Solenoid Valve
Rubber Seal
Series VF1000/3000/5000
Large flow capacity
Yet compact size.
Low power consumption
1.8 W (DC)
Exhausting equipment for pilot valve not required.
Common exhaust port for main and pilot valve (VF1000/3000)
www.DataSheet.net/
VF5000
C: 12 dm3/(s·bar)
{4/2 Ǟ 5/3 (A/B Ǟ EA/EB)}
32 mm width
VF3000
C: 3.1 dm3/(s·bar)
VF1000 {4/2 Ǟ 5/3 (A/B Ǟ EA/EB)}
C: 0.53 dm3/(s·bar) 26.4 mm width
{4/2 Ǟ 5/3 (A/B Ǟ EA/EB)}
26.4 mm width
VK
VZ
VF
VFR
VP4
VZS
VFS
VS4
VQ7
EVS
VFN
3-4-1
Datasheet pdf - http://www.DataSheet4U.co.kr/

1 Page





VF3530 pdf, ピン配列
3
Series VF1000/3000/5000
Precautions
Be sure to read before handling. For Safety Instructions and Solenoid Valve Precautions, refer to page 3-13-2.
Light/Surge Voltage Suppressor
Caution
Grommet terminal (E)
Conduit terminal (T)
Grommet (G) DIN terminal (Y)
L plug connector (L)
M plug connector (M)
S
AC
Z
Neon
bulb
EZ, TZ, DZ, LZ, MZ
(100 VAC or more)
Red
S
Black
DC
Z
EZ, TZ, DZ, LZ, MZ
(24 VAC or less)
Neon
bulb
EZ, TZ, DZ, LZ, MZ
(100 VDC or more)
EZ, TZ, DZ, LZ, MZ
(24 VDC or less)
Note) W/surge voltage suppressor is available only
for grommet type.
Common Exhaust Type for Main and Pilot
Exhaust air from pilot valve will flow to
main valve exhaust port. Exhaust air from
main valve will not flow to pilot valve side
due to a check valve.
Purpose
• Not to exhaust mist from PE (Pilot
Exhaust) port to protect the surrounding
environment
• To lower the exhaust noise from PE port
when switching valve.
• To prevent silencer mounted to PE port
from getting plugged in dusty
environments.
Caution
Common exhaust valves are effective for
use with common exhaust manifolds,
however an exhaust cleaner (Series
AMC) should be installed when used in
this manner. Make sure the exhaust port
operates properly after installing the
exhaust cleaner.
Used as a 3 Port Valve
Plugging one of the cylinder ports (A or B)
enables use as a normally closed (N.C.)
or normally open (N.O.) 3 portwww.DataSheet.net/ valve.
It is convenient when 3 port valve is
needed on a manifold, etc., but it can’t be
used in special applications such as using
as a non-leakage valve. Use it with the
exhaust port leaving open.
Plug
Type of
actuation
B port
(CYL. 1 port)
N.C.
(X) plug
A port
(CYL. 2 port)
N.O.
(X) plug
(X) plug
(X) plug
Interchangeability with V1000 and V3000
V1000 and V3000 are respectively inter-
changeable with VF1000 and VF3000.
Mounts are the same however, care must
be taken because the main valve
switching differs from the VF3000 to the
V3000.
1. When cylinder port is body ported.
Port position of CYL1 and CYL2 are
opposites. Make sure of the port
symbol and pipe so that back actuation
does not occur.
VF3000
B(CYL.1) A(CYL.2)
V3000
CYL.2
CYL.1
VK
VZ
VF
VFR
VP4
VZS
VFS
2. When cylinder port is base mounted.
When the VF3000 is installed on
sub–plate or base mounted manifold
(B1, B2) in the same position with
V3000, air flow will be reversed. Follow
either of these installation procedures.
A. Install the VF3000 on the sub-plate
or manifold base in the opposite
direction.
B. Install the VF3000 in the same
position as the V3000 but reverse the
piping of the CYL port.
VS4
VQ7
EVS
VFN
Wiring
Grommet with surge voltage suppressor
at DC voltage has +/– direction. Connect
to the power source as follows.
DIN connection and Terminal connection
are free from +/– direction. Connect no.1
and 2 terminals to the power source.
For Grommet
Lead wire color Red Black
Wiring
+–
DIN terminal and Terminal
With DIN terminal
block
With terminal
block
Ground
• Applicable cable O.D.
Type D : ø6 to ø8 mm
Type Y : ø4.5 to ø7 mm
Type T : ø6 to ø8 mm
Type E : ø2.3 to ø2.8 mm
• Applicable crimp terminal
Type E, T: 1.25-3, 1.25-3S, 1.25Y-3N,
1.25Y-3S
( )“Type R” or “Type Y” crimp terminal
can not be used in “Type D, Y”.
3-4-3
Datasheet pdf - http://www.DataSheet4U.co.kr/


3Pages


VF3530 電子部品, 半導体
Series VF1000
6
How to Order
Body ported VF1 1 2 0
1L
Port size
(P, A, B)
M5 M5 x 0.8
01 1 8
EA, EB
port: M5 x 0.8
01
Thread type
Nil Rc
FG
N NPT
T NPTF
Only when 01
(1/8)
Option
F With bracket
Not installed
when delivered
Manifold VF1 1 3 0 1 L
01
Type of
actuation
1 Single solenoid
2 Double solenoid
Body option
0 Standard
Common exhaust
3 type for main and
pilot valve
Option
Construction
Single solenoid
Coil rated
voltage
Electrical entry
1 100 VAC, 50/60 Hz G Grommet (Lead wire: 300 mm)
2 200 VAC, 50/60 Hz H Grommet (Lead wire: 600 mm)
3 110 V to 120 VAC, 50/60 Hz E Grommet terminal
4 220 VAC, 50/60 Hz T
Conduit terminal
5 24 VDC
6 12 VDC
D DIN With connector
DO terminal Without connector
7 240 VAC, 50/60 Hz
9 Other
Option
L With lead wire
L plug
LN connector Without lead wire
LO Without connector
L, M plug
M
With lead wire
connector:
Max. 220 VAC
M plug
MN connector Without lead wire
MO Without connector
Port size
(A, B)
M5 M5 x 0.8
01 1 8
Manual override
Nil Non-locking push type
B Locking type B
C Locking type C
Light/Surge voltage suppressor
Nil None
Z With light/surge voltage suppressor
S With surge voltage suppressor
Indicator light is not available for grommet type.
W/surge voltage suppressor is available for
grommet type only.
How to Order Pilot Valve Assembly
SF4 1 DZ 50
Double solenoid
Component Parts
No. Description
q Body
w Adapter plate
e End cover
r Pilot body
t Pilot cover
y Piston
u Spool valve
Material
Aluminum die-casted
Resin
Aluminum die-casted
Resin
Resin
Resin
Aluminum, NBR
Note
Platinum silver
Black
Black
Replacement Parts
No. Description
i Pilot valve assembly Note)
Material
Part no.
SF4-„„„-50
Note) Refer to “How to Order Pilot Valve Assembly” on the right above.
www.DataSheet.net/
(A) (B) (C)
(A) Coil rated
voltage
(B) Electrical entry, Light/surge
voltage suppressor
1 100 VAC, 50/60 Hz
2 200 VAC, 50/60 Hz
3 110 to 120 VAC, 50/60 Hz
4 220 VAC, 50/60 Hz
5 24 VDC
6 12 VDC
7 240 VAC, 50/60 Hz
9 Other
Option
(C) Manual
override
Nil Non-locking push type
B Locking type B
C Locking type C
Symbol Electrical entry Light/Surge voltage suppressor
G
Lead wire length
None
GS
H
300 mm
Grommet
Lead wire length
With surge voltage suppressor
None
HS 600 mm With surge voltage suppressor
E Grommet terminal
None
EZ With light/surge voltage suppressor
T Conduit terminal
None
TZ With light/surge voltage suppressor
D With None
DZ DIN connector With light/surge voltage suppressor
DO terminal Without
None
DOZ
connector With light/surge voltage suppressor
L
With lead
None
LZ wire With light/surge voltage suppressor
LN L plug Without lead
None
LNZ connector wire With light/surge voltage suppressor
LO
LOZ
Without
None
connector With light/surge voltage suppressor
M
With lead
None
MZ wire With light/surge voltage suppressor
MN M plug Without lead
None
MNZ connector wire With light/surge voltage suppressor
MO Without None
MOZ
connector With light/surge voltage suppressor
Note) Interchangeable with the previous
model DXT154-A-„„„„
3-4-6
Datasheet pdf - http://www.DataSheet4U.co.kr/

6 Page



ページ 合計 : 30 ページ
 
PDF
ダウンロード
[ VF3530 データシート.PDF ]


データシートを活用すると、その部品の主な機能と仕様を詳しく理解できます。 ピン構成、電気的特性、動作パラメータ、性能を確認してください。


共有リンク

Link :


部品番号部品説明メーカ
VF3530

5 Port Pilot Operated Solenoid Valve Rubber Seal

SMC
SMC


www.DataSheet.jp    |   2020   |  メール    |   最新    |   Sitemap