DataSheet.jp

GM1851 の電気的特性と機能

GM1851のメーカーはUnisonic Technologiesです、この部品の機能は「GROUND FAULT INTERRUPTER」です。


製品の詳細 ( Datasheet PDF )

部品番号 GM1851
部品説明 GROUND FAULT INTERRUPTER
メーカ Unisonic Technologies
ロゴ Unisonic Technologies ロゴ 




このページの下部にプレビューとGM1851ダウンロード(pdfファイル)リンクがあります。
Total 10 pages

No Preview Available !

GM1851 Datasheet, GM1851 PDF,ピン配置, 機能
UNISONIC TECHNOLOGIES CO., LTD
GM1851
LINEAR INTEGRATED CIRCUIT
GROUND FAULT
INTERRUPTER
„ DESCRIPTION
The UTC GM1851 can specially provide ground fault protection
for AC power outlets in consumer and industrial environments. As
ground fault currents greater than a presentable threshold value, it
will trigger an external SCR-driven circuit breaker to interrupt the
AC line and remove the fault condition. Besides of detection of
conventional hot wire to ground faults, the neutral fault condition is
detected also. In the event that noise pulses introduce unwanted
charging currents and a memory circuit that allows firing of even a
sluggish breaker on either half-cycle of the line voltage when
external full-wave rectification is used, circuitry that rapidly resets
the timing capacitor.
„ FEATURES
Lead-free: GM1851L
Halogen-free: GM1851G
* Internal power supply shunt regulator
* Externally programmable fault current threshold
* Externally programmable fault current integration time
* Direct interface to SCR
* Operates under line reversal; both load vs line and hot vs neutral
* Detects neutral line faults
„ ORDERING INFORMATION
Normal
GM1851-S08-R
GM1851-D08-T
Ordering Number
Lead Free
GM1851L-S08-R
GM1851L-D08-T
Halogen Free
GM1851G-S08-R
GM1851G-D08-T
Package
SOP-8
DIP-8
Packing
Tape Reel
Tube
www.DataSheet4U.com
www.unisonic.com.tw
Copyright © 2008 Unisonic Technologies Co., Ltd
1 of 10
QW-R122-007,B

1 Page





GM1851 pdf, ピン配列
GM1851
„ INTERNAL SCHEMATIC DIAGRAM
LINEAR INTEGRATED CIRCUIT
www.DataSheet4U.com
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
3 of 10
QW-R122-007,B


3Pages


GM1851 電子部品, 半導体
GM1851
LINEAR INTEGRATED CIRCUIT
„ CIRCUIT DESCRIPTION (Refer to Block and Connection Diagram)
The UTC GM1851 operates from 26V as set by an internal shunt regulator, D3. In the absence of a fault (If=0) the
feedback path status signal (VS) is correspondingly zero. Under these conditions the capacitor discharge current, I1,
sits quiescently at three times its threshold value, ITH, so that noise induced charge on the timing capacitor will be
rapidly removed. When a fault current, If, is induced in the secondary of the external sense transformer, the
operational amplifier, A1, uses feedback to force a virtual ground at the input as it extracts If. The presence of If
during either half-cycle will cause VS to go high, which in turn changes I1 from 3ITH to ITH. Although ITH discharges
the timing capacitor during both half-cycles of the line, If only charges the capacitor during the half-cycle in which If
exits pin 2. Thus during one half-cycle If-ITH charges the timing capacitor, while during the other half-cycle ITH
discharges it. When the capacitor voltage reaches 17.5V, the latch engages and turns off Q3 permitting I2 to drive
the gate of an SCR.
„ APPLICATION CIRCUITS
A typical ground fault interrupter circuit is shown in Figure 2. It is designed to operate on 120 VAC line voltage with
5 mA normal fault sensitivity.
A full-wave rectifier bridge and a 15k/2W resistor are used to supply the DC power required by the IC. A 1μF
capacitor at pin 8 used to filter the ripple of the supply voltage and is also connected across the SCR to allow firing of
the SCR on either half-cycle. When a fault causes the SCR to trigger, the circuit breaker is energized and line
voltage is removed from the load. At this time no fault current flows and the IC discharge current increases from ITH
to 3ITH ( see Circuit Description and Block Diagram ). This quickly resets both the timing capacitor and the output
latch. At this time the circuit breaker can be reset and the line voltage again supplied to the load, assuming the fault
has been removed. A 1000:1 sense transformer is used to detect the normal fault. The fault current, which is
basically the difference current between the hot and neutral lines, is stepped down by 1000 and fed into the input
pins of the operational amplifier through a 10μF capacitor. The 0.0033μF capacitor between pin 2 and pin 3 and the
200 pF between pins 3 and 4 are added to obtain better noise immunity. The normal fault sensitivity is determined by
the timing capacitor discharging current, ITH. ITH can be calculated by:
ITH=
7V
RSET
÷2
(1)
At the decision point, the average fault current just equals the threshold current, ITH.
ITH=
If (rms)
2
× 0.91
(2)
Where If(rms) is the rms input fault current to the operational amp and the factor of 2 is due to the fact that If
charges the timing capacitor only during one half-cycle, while ITH discharges the capacitor continuously. The factor
0.91 converts the rms value to an average value. Combining equations (1) and (2) we have
RSET=
7V
If (rms) × 0.91
(3)
For example, to obtain 5mA (rms) sensitivity for the circuit in Figure 2 we have:
RSET=
7V
5mA × 0.91
=1.5MΩ
1000
(4)
The correct value for RSET can also be determined from the characteristic curve that plots equation (3). Note that
this is an approximate calculation; the exact value of RSET depends on the specific sense transformer used and
UTC GM1851 tolerances. Inasmuch as UL943 specifies a sensitivity '' window '' of 4mA ~ 6mA, provision should be
made to adjust RSET on a per-product basis.
Independent of setting sensitivity, the desired integration time can be obtained through proper selection of the
timing capacitor, Ct. Due to the large number of variables involved, proper selection of Ct is best done empirically.
The following design example, then should only be used as a guideline.
www.DataSAhseseut4mUe.cthoemgoal is to meet UL943 timing requirements. Also assume that worst-case timing occurs during GF1
Start-up (S1 closure) with both a heavy normal fault and a 2grounded neutral fault present. This situation is shown
diagrammatically below.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
6 of 10
QW-R122-007,B

6 Page



ページ 合計 : 10 ページ
 
PDF
ダウンロード
[ GM1851 データシート.PDF ]


データシートを活用すると、その部品の主な機能と仕様を詳しく理解できます。 ピン構成、電気的特性、動作パラメータ、性能を確認してください。


共有リンク

Link :


部品番号部品説明メーカ
GM1851

GROUND FAULT INTERRUPTER

Unisonic Technologies