DataSheet.jp

G3VM-21LR の電気的特性と機能

G3VM-21LRのメーカーはOmronです、この部品の機能は「MOS FET Relays」です。


製品の詳細 ( Datasheet PDF )

部品番号 G3VM-21LR
部品説明 MOS FET Relays
メーカ Omron
ロゴ Omron ロゴ 




このページの下部にプレビューとG3VM-21LRダウンロード(pdfファイル)リンクがあります。

Total 6 pages

No Preview Available !

G3VM-21LR Datasheet, G3VM-21LR PDF,ピン配置, 機能
MOS FET Relays
G3VM-21LR
www.DataSheet4U.com
World’s Smallest SSOP Package MOS FET Relay*
with Low Output Capacitance and ON Resistance
(C×R = 5pF• Ω) in a 20-V Load Voltage Model
• Output capacitance of 1 pF (typical) allows high frequency
applications.
• RoHS Compliant.
*Information correct as of May, 2007, according to data obtained by OMRON.
Application Examples
Semiconductor inspection tools
Measurement devices and Data loggers
Broadband systems
Note: The actual product is marked differently from the image shown
here.
List of Models
Contact form
Terminals
SPST-NO
Surface-mounting
terminals
Load voltage (peak value)
Model
20 VAC
G3VM-21LR
G3VM-21LR(TR)
G3VM-21LR(TR05)
G3VM-21LR(TR10)
Number per tape
---
1,500
500
1,000
Dimensions
Note: All units are in millimeters unless otherwise indicated.
G3VM-21LR
4.2
228
1.7
1.4 dia.
Note: The actual product is marked differently from
the image shown here.
0.3
1.27
2.04
3.5
0.15 1.8
Note: A tolerance of ±0.1 mm applies to
all dimensions unless otherwise
0.2 specified.
3.8
0.46±0.2
Weight: 0.03 g
Terminal Arrangement/Internal Connections (Top View)
G3VM-21LR
43
12
Actual Mounting Pad Dimensions (Recommended Value, Top View)
G3VM-21LR
0.95 3.73
0.8
1.27
MOS FET Relays G3VM-21LR 231

1 Page





G3VM-21LR pdf, ピン配列
Engineering Data
LED forward current vs.
Ambient temperature
IF - Ta
100
80
60
40
20
0-20 0 20 40 60 80 100 120
Ambient temperature Ta ()
Continuous load current vs.
On-state voltage
IO - VON
200
Ta = 25 °C
150 I F = 5 mA
100
50
0
-50
-100
-150
-200-1
-0.5 0 0.5
On-state voltage VON (V)
1
Turn ON, Turn OFF time vs.
LED forward current
tON, tOFF - IF
1000
Ta = 25 °C
300 V DD = 10 V, RL = 200 Ω
100
t OFF
30
10
3 t ON
11 3
10 30
LED forward current IF (mA)
100
Output terminal capacitance
COFF/COFF(ov) vs. Load voltage
COFFVOFF
1
Ta = 25
0.8
0.6
0.4
0.2
Continuous load current vs.
Ambient temperature
IO - Ta
280
240
200
160
120
80
40
0-20 0 20 40 60 80 100 120
Ambient temperature Ta ഒ
On-state resistance vs.
Ambient temperature
RON - Ta
10
I O = 160 mA
I F = 5 mA
8 t < 1s
6
4
2
0-20 0 20 40 60 80 100
Ambient temperature Ta ()
Turn ON, Turn OFF time vs.
Ambient temperature
tON, tOFF - Ta
250
V DD = 10 V, RL = 200 Ω
I F = 10 mA
200
150 t OFF
100
50 t ON
0-20 0
20 40 60 80 100
Ambient temperature Ta (
0 10 20
Load voltage VOFF(v)
30
www.DataSheet4U.com
LED forward current vs.
LED forward voltage
IF - VF
100
50 Ta = 25 °C
30
10
5
3
1
0.5
0.3
0.1
0.6
0.8
1 1.2 1.4 1.6 1.8
LED forward voltage VF (V)
Trigger LED forward current vs.
Ambient temperature
IFT - Ta
5
I O = 100 mA
t < 1s
4
3
2
1
0-20 0 20 40 60 80 100
Ambient temperature Ta ()
Current leakage vs.
Load voltage
I LEAK – VOFF
15
Ta = 25 °C
10
5
0 5 10 15 20
Load voltage VOFF(v)
MOS FET Relays G3VM-21LR 233


3Pages


G3VM-21LR 電子部品, 半導体
Certain Precautions on Specifications and Use www.DataSheet4U.com
1. Suitability for Use. Seller shall not be responsible for conformity with any stan-
dards, codes or regulations which apply to the combination of the Product in
Buyer's application or use of the Product. At Buyer's request, Seller will pro-
vide applicable third party certification documents identifying ratings and limi-
tations of use which apply to the Product. This information by itself is not
sufficient for a complete determination of the suitability of the Product in com-
bination with the end product, machine, system, or other application or use.
Buyer shall be solely responsible for determining appropriateness of the par-
ticular Product with respect to Buyer's application, product or system. Buyer
shall take application responsibility in all cases but the following is a non-
exhaustive list of applications for which particular attention must be given:
(i) Outdoor use, uses involving potential chemical contamination or electrical
interference, or conditions or uses not described in this document.
(ii) Energy control systems, combustion systems, railroad systems, aviation
systems, medical equipment, amusement machines, vehicles, safety
equipment, and installations subject to separate industry or government
regulations.
(iii) Use in consumer products or any use in significant quantities.
(iv) Systems, machines and equipment that could present a risk to life or
property. Please know and observe all prohibitions of use applicable to this
product.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS
RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT
THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE
INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
2. Programmable Products. Seller shall not be responsible for the user's pro-
gramming of a programmable product, or any consequence thereof.
3. Performance Data. Performance data given in this publication is provided as
a guide for the user in determining suitability and does not constitute a war-
ranty. It may represent the result of Seller's test conditions, and the users must
correlate it to actual application requirements. Actual performance is subject to
Seller's Warranty and Limitations of Liability.
4. Change in Specifications. Product specifications and accessories may be
changed at any time based on improvements and other reasons. It is our prac-
tice to change part numbers when published ratings or features are changed,
or when significant construction changes are made. However, some specifica-
tions of the Product may be changed without any notice. When in doubt, spe-
cial part numbers may be assigned to fix or establish key specifications for
your application. Please consult with your Seller representative at any time to
confirm actual specifications of purchased Product.
5. Errors and Omissions. The information in this publication has been carefully
checked and is believed to be accurate; however, no responsibility is assumed
for clerical, typographical or proofreading errors, or omissions.
6. RoHS Compliance. Where indicated, our products currently comply, to the
best of our knowledge as of the date of this publication, with the requirements
of the European Union's Directive on the Restriction of certain Hazardous
Substances ("RoHS"), although the requirements of RoHS do not take effect
until July 2006. These requirements may be subject to change. Please consult
our website for current information.
Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website
at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
Cat. No. X302-E-1
08/09
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
Specifications subject to change without notice
Printed in USA
MOS FET Relays G3VM-21LR

6 Page



ページ 合計 : 6 ページ
 
PDF
ダウンロード
[ G3VM-21LR データシート.PDF ]


データシートを活用すると、その部品の主な機能と仕様を詳しく理解できます。 ピン構成、電気的特性、動作パラメータ、性能を確認してください。


共有リンク

Link :


部品番号部品説明メーカ
G3VM-21LR

MOS FET Relays

Omron
Omron
G3VM-21LR1

MOS FET Relays

Omron
Omron
G3VM-21LR11

MOS FET Relays

Omron
Omron


www.DataSheet.jp    |   2020   |  メール    |   最新    |   Sitemap