Intelligent Flag I/II
V600-HA
Innovative RFID Electronic Flags to
Replace Mechanical Flag and Kanban
Systems
• Doesn't need a program and can be used like a sensor.
• Advanced line construction at minimal cost.
• Saves space.
• Precise installation not required (Transmission distance:
www.DataSh1e0et04Um.cmommax.).
• A verification function provided on multi-functional type.
• Addition of 16-bit models to the series responds to applica-
tions from Kanban to quality control.
• Equipped with a wiring reduction mode and communications
parity check function (16-bit models).
• Both NPN and PNP output available.
• FCC certified.
Ordering Information/Specifications
■ Amplifier
Type
Read-only (8-bit)
Multi-functional (8-bit)
Read-only (16-bit)
Item
Model V600-HAR91
V600-HAR81
V600-HAM91
V600-HAM81
V600-HAR92
Power supply
24 VDC ±10%, ripple (p-p): 10%
Current consumption 130 mA max.
Input
Transistor output or contact output
Short-circuit current: 3 mA (typical) (IN terminal and 0-V short-circuit)
OFF voltage:
15 to 30 VDC
ON voltage:
0 to 5 VDC
Input impedance: 8.2 kΩ
Applied voltage: 30 VDC max.
Transistor output
OFF voltage:
15 to 30 VDC
Input impedance:
8.2 kΩ
Short-circuit current:
3 mA (typical) (for 0-V short-circuit of
INHIBIT/TRG)
ON voltage:
0 to 5 VDC
Applied voltage:
30 VDC max.
Output
NPN open collector
output, 20 mA max. at
30 VDC, residual volt-
age: 2 V max.
PNP open collector
output, 20 mA max.
at 30 VDC, residual
voltage: 2 V max.
NPN open collector PNP open collector out- NPN open collector output, 20 mA
output, 20 mA max. at put, 20 mA max. at 30 max. at 30 VDC, residual voltage: 2 V
30 VDC, residual volt- VDC, residual voltage: 2 V max.
age: 2 V max.
max.
Diagnostic functions Checks for CPU errors and transmission errors
Insulation resistance 50 MΩ max. (at 500 VDC) between cable terminals and case
Dielectric strength 500 VAC, 50/60 Hz for 1 min between cable terminals and case (leakage current: 1 mA max.)
2 Intelligent Flag I/II V600-HA
1 Page ■ Sensor
Model
Shape
V600-HS51
V600-HS61
V600-HS63
V600-HS67
Item
Transmission frequency
Ambient temperature
Storage temperature
Ambient humidity
Insulation resistance
Dielectric strength
Degree of protection
Vibration resistance
www.DataSheet4U.com
Shock resistance
Cable length
Wireless transmission
error direction
Indicator
Weight
530 kHz
−10 to 60°C
−10 to 70°C
−25 to 75°C
35% to 95%
50 MΩ (at 500 VDC) between cable terminal and case
1,000 VAC, 50/60 Hz for 1 min between cable terminal and case (leakage current: 1 mA max.)
IEC60529: IP67
Destruction: 10 to 2,000 Hz, 3-mm double amplitude, with Destruction: 10 to 500 Hz, 2-mm double amplitude, with 3
2 sweeps of 15 min each in 3 directions
sweeps of 11 min each in 3 directions
Destruction: 981 m/s2, 3 times each in 3 directions (18 Destruction: 490 m/s2, 3 times each in 3 directions (18
times total)
times total)
2 m (fixed)
16-bit CRC (Cyclic Redundancy Check) in both directions
---
Approx. 70 g
Power: green
Approx. 190 g
Approx. 540 g
■ Transmission Distance Specifications
Recommended Combinations
Amplifier
Data Carrier
Sensor
V600-HS51
Memory
EEPROM
(Battery-
less type)
V600-D23P53
V600-D23P54
V600-D23P55
0.5 to 3.0 mm
0.5 to 5.0 mm
0.5 to 7.0 mm
V600-D23P61
0.5 to 8.0 mm
V600-D23P66N ---
V600-D23P66SP ---
V600-D23P71
---
V600-D23P72
---
Memory
SRAM
(Built-in-
battery
type)
V600-D8KR12
V600-D8KR13
V600-D8KR04
V600-D2KR16
5 to 15 mm
---
---
---
V600-HAR91/-HAR81/-HAM91/-HAM81/-HAR92
V600-HS61
V600-HS63
0.5 to 3.0 mm
---
0.5 to 5.5 mm
---
0.5 to 7.0 mm
0.5 to 9.5 mm
0.5 to 9.0 mm
2 to 16 mm
--- 5 to 30 mm
--- 5 to 25 mm
--- 5 to 35 mm
0.5 to 18 mm
5 to 35 mm
5 to 18 mm
5 to 45 mm
--- 10 to 30 mm
--- 10 to 65 mm
--- 2 to 15 mm
V600-HS67
---
---
---
---
5 to 35 mm
5 to 30 mm
10 to 70 mm
10 to 50 mm
10 to 60 mm
10 to 40 mm
10 to 100 mm
---
Note: 1. The specifications take fluctuations in ambient temperature and slight differences between products into account.
2. The read distance and write distance are the same.
3. Sensor Installation Conditions
• V600-HS51:When flush-mounted in iron
Axial offset from the Data Carrier: ±2.0 mm
• V600-HS61: When surface-mounted on metal (ferrous)
Axial offset from the Data Carrier: ±2.0 mm
• V600-HS63: When surface-mounted on metal (ferrous)
Axial offset from the Data Carrier: ±10.0 mm
• V600-HS67: When surface-mounted on metal (ferrous)
Axial offset from the Data Carrier: ±10.0 mm
4. Data Carrier Installation Conditions
• V600-D23P53/-P54: When flush-mounted in iron
• V600-D23P55/-P66N/-P66SP/-P71/-P72: When surface-mounted on resin (no metal on the backside)
• V600-D23P61: When surface-mounted on metal (ferrous)
• V600-D8KR12/-13/-04: When surface-mounted on metal (ferrous)
• V600-D2KR16: When the Data Carrier attached to the holder is mounted on a metal (ferrous) surface
5. The transmission distance specified in the specifications is also applicable when the Data Carrier is mounted on non-metallic surfaces.
6. The Data Carrier is stationary.
4 Intelligent Flag I/II V600-HA
3Pages Combinations with the V600-HS63 Sensor
V600-HS63 & V600-D23P55
V600-HS63 & V600-D23P61
YY
30
X
20
Y
30
20
10 10
Y
X
–30 –20 –10 0
10 20 30 X
–40 –30 –20 –10 0 10 20 30 40 X
V600-HS63 & V600-D23P66N
Y
50 Y
40
X
30
20
10
–50 –40 –30 –20 –10 0 10 20 30 40 50 X
V600-HS63 & V600-D23P66SP
www.DataSheet4U.com
Y
50
40
30
Y
X
20
10
–50 –40 –30 –20 –10 0 10 20 30 40 50 X
V600-HS63 & V600-D23P71
Y
60
40
20
Y
X
–60 –40 –20 0
20 40 60 X
V600-HS63 & V600-D23P72
YY
60
X
40
20
–60 –40 –20 0 20 40 60 X
V600-HS63 & V600-D8KR12
YY
60
X
40
20
–60 –40 –20 0 20 40 60 X
V600-HS63 & V600-D8KR04
YY
80
X
60
40
20
–80 –60 –40 –20 0 20 40 60 80 X
V600-HS63 & V600-D2KR16
YY
60
X
40
20
–80 –60 –40 –20 0 20 40 60 80 X
Intelligent Flag I/II V600-HA
7
6 Page | |||
ページ | 合計 : 15 ページ | ||
|
PDF ダウンロード | [ V600-HAR91 データシート.PDF ] |
データシートを活用すると、その部品の主な機能と仕様を詳しく理解できます。 ピン構成、電気的特性、動作パラメータ、性能を確認してください。 |
部品番号 | 部品説明 | メーカ |
V600-HAR91 | Intelligent Flag I/II | Omron |
V600-HAR91 | Intelligent Flag I/II | Omron |
V600-HAR91 | RFID System Applications | Omron |
V600-HAR91 | V600 ID Systems | Omron |