DataSheet.es    


PDF GCU04AA-130 Data sheet ( Hoja de datos )

Número de pieza GCU04AA-130
Descripción HIGH POWER INVERTER USE PRESS PACK TYPE
Fabricantes Mitsubishi Electric 
Logotipo Mitsubishi Electric Logotipo



Hay una vista previa y un enlace de descarga de GCU04AA-130 (archivo pdf) en la parte inferior de esta página.


Total 6 Páginas

No Preview Available ! GCU04AA-130 Hoja de datos, Descripción, Manual

GCU04AA-130
MITSUBISHI GCT (Gate Commutated Turn-off) THYRISTOR UNIT
GCU04AA-130
HIGH POWER INVERTER USE
PRESS PACK TYPE
q Symmetrical GCT unit
q GCT and gate driver are connected
q ITQRM: Repetitive controllable on-state current ........ 400A
q IT(AV): Average on-state current ..................... 180A
q VDRM: Repetitive peak off-state voltage ....... 6500V
q VRRM: Repetitive peak reverse voltage ........ 6500V
q Tj: Operation junction temperature ......... 125°C
APPLICATION
Current source inverters, DC choppers, Induction heaters, DC to DC converter
OUTLINE DRAWING
Dimensions in mm
www.DataSheet4U.com
(208)
(104)
φ38±0.2 (68)
(170)
(R39.5)
(20)
9MAX
GATE TEST POINT
CATHODE TEST POINT
LED4 : POWER SUPPLY OK (GREEN)
LED3 : G-K OK (GREEN)
LED2 : GATE ON (YELLOW)
LED1 : GATE OFF (RED)
20V POWER SUPPLY INPUT
(MSTB2.5/2-G-5.08AU)
FIBER OPTIC INPUT (HFBR-2521)
FAULT SIGNAL OUTPUT (HFBR-1521)
(5)
(37)
6±0.5
160MIN
(120)
6±0.5
20±1V
12
6±0.5
φ38±0.2
6±0.5
Mar. 2004

1 page




GCU04AA-130 pdf
Note 1. Status signal
1. Status signal from LED
(1) Status signal
Status of GCT
On state
Off state
LED 1
(Red)
OFF
ON
MITSUBISHI GCT (Gate Commutated Turn-off) THYRISTOR UNIT
GCU04AA-130
HIGH POWER INVERTER USE
PRESS PACK TYPE
LED 2
(Yellow)
ON
OFF
(2) Fault signal
Status
Normal
Fault
Fault
Fault
G-K
Normal
Normal
G-K short
G-K short
Power Supply
20±1V
Voltage down
20±1V
Voltage down
G-K LED (LED 3)
(Green)
On
Off
Off
Off
PS LED (LED 4)
(Green)
On
Off
On
Off
2. Status signal from Transmitter
(1) Normal operation
Control signal
(Control board)
Control signal
(GDU input)
Status signal
(GDU output)
L
NL
L
NL
L
NL
(3) Fault signal (G-K short)
Control signal
(Control board)
Control signal
(GDU input)
Status signal
(GDU output)
NL
NL
L
Normal
L
L
NL
Fault
(L : Light NL : No light)
(2) Fault signal (O/V or U/V)
Control signal
(Control board)
Control signal
(GDU input)
Status signal
(GDU output)
L
NL
L
NL
L
L
NL
Normal
Fault
(4) Fault signal (fiber optic)
Control signal
(Control board)
NL
L
Control signal
(GDU input)
Status signal
(GDU output)
NL
L
(Always No light)
(Always light)
Mar. 2004

5 Page










PáginasTotal 6 Páginas
PDF Descargar[ Datasheet GCU04AA-130.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
GCU04AA-130HIGH POWER INVERTER USE PRESS PACK TYPEMitsubishi Electric
Mitsubishi Electric

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar